
HPLC Columns
- (4)
- (1)
- (16)
- (9)
- (3)
- (3)
- (5)
- (18)
- (6)
- (5)
- (6)
- (1)
- (2)
- (10)
- (250)
- (1)
- (1)
- (2)
- (9)
- (304)
- (10)
- (2)
- (2)
- (1)
- (1)
- (1)
- (205)
- (1,347)
- (4)
- (4)
- (162)
- (1)
- (1)
- (83)
- (20)
- (9)
- (90)
- (900)
- (1)
- (13)
- (2)
- (162)
- (12)
- (4)
- (440)
- (17)
- (1,597)
- (2)
- (2)
- (8)
- (1)
- (86)
- (7)
- (35)
- (2)
- (9)
- (3)
- (30)
- (9)
- (83)
- (1)
- (25)
- (1)
- (9)
- (10)
- (11)
- (5)
- (320)
- (222)
- (1)
- (789)
- (7)
- (1)
- (1)
- (146)
- (459)
- (971)
- (1)
- (56)
- (1)
- (72)
- (53)
- (1)
- (351)
- (25)
- (811)
- (114)
- (1)
- (21)
- (101)
- (1)
- (223)
- (24)
- (2)
- (3)
- (10)
- (1)
- (2)
- (10)
- (11)
- (2)
- (241)
- (63)
- (1)
- (728)
- (12)
- (1)
- (9)
- (15)
- (2)
- (3)
- (130)
- (1)
- (11)
- (5)
- (16)
- (2)
- (3)
- (27)
- (39)
- (87)
- (440)
- (25)
- (2)
- (33)
- (3)
- (13)
- (167)
- (29)
- (15)
- (12)
- (6)
- (139)
- (446)
- (13)
- (4)
- (1,129)
- (30)
- (22)
- (3)
- (2)
- (1)
- (80)
- (24)
- (2,873)
- (10)
- (5)
- (2)
- (24)
- (2)
- (24)
- (17)
- (27)
- (5)
- (4)
- (1)
- (1)
- (4)
- (1,181)
- (3)
- (1)
- (4)
- (4)
- (456)
- (19)
- (648)
- (18)
- (276)
- (3)
- (12)
- (2)
- (144)
- (261)
- (5)
- (141)
- (2)
- (13)
- (141)
- (450)
- (49)
- (125)
- (5)
- (70)
- (5)
- (6)
- (3)
- (63)
- (5)
- (191)
- (11)
- (7)
- (8)
- (6)
- (84)
- (3)
- (1)
- (5)
- (147)
- (1)
- (1)
- (629)
- (22)
- (89)
- (7)
- (7)
- (13)
- (11)
- (412)
- (41)
- (105)
- (35)
- (14)
- (131)
- (11)
- (2)
- (2)
- (13)
- (210)
- (77)
- (10)
- (1)
- (227)
- (2)
- (8)
- (45)
- (3,451)
- (65)
- (13)
- (3)
- (1)
- (1)
- (9)
- (7)
- (3)
- (29)
- (83)
- (31)
- (2)
- (11)
- (4)
- (71)
- (1)
- (4)
- (4)
- (1)
Filtered Search Results

Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.

Carbon Load | 11% |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil™ ODS C18 Columns

Use as a general purpose C18 phase for acidic and neutral analytes.

Pore Size | 120 Å |
---|---|
Carbon Load | 10% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns

Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients

Thermo Scientific™ Acclaim™ 120 C18 Columns

Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
Pore Size | 120 Å |
---|---|
Carbon Load | 18% |
Stationary Phase | C18 |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 300 m²/g |
USP Type | L1 |
Thermo Scientific™ EASY-Spray™ HPLC Columns
Robust capillary flow HPLC columns for sensitive protein, peptide and mAbs separation using the stand alone or integrated easy to use design.

Phase | Reversed Phase |
---|
Thermo Scientific™ Acclaim™ Polar Advantage II HPLC Columns

Resolve polar and nonpolar compounds in a single run. These columns have high pH stability (pH 1.5–10) in the separation of basic, neutral, and acidic species.
Pore Size | 120 Å |
---|---|
Stationary Phase | Polar Embedded |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Reversed Phase |
Surface Area | 300 m²/g |
USP Type | L60 |
Thermo Scientific™ Acclaim™ PepMap™ 100 C18 HPLC Columns

Use for high-resolution tryptic, natural, and synthetic peptide analyses. Its high loading capacity is exceptional for low abundant peptides in complex proteomic samples.

Pore Size | 100 Å |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
USP Type | L1 |
Thermo Scientific™ BetaSil™ C18 HPLC Columns, 5μm Particle Size

High surface area with high bonded phase coverage
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 20% |
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 310 m²/g |
USP Type | L1 |
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Type | Column |
Stationary Phase | C18 |
Phase | Reversed Phase |
Packing Material | Silica |
Column Type | Reversed Phase |
Quantity | 1/Pk. |
Material | Stainless Steel |
Surface Area | 350 m²/g |
USP Type | L1 |
Thermo Scientific™ Acclaim™ Mixed Mode WCX-1 HPLC Columns

Separate cationic molecules with powerful adjustable selectivity control using this mixed-mode reversed-phase and weak cation-exchange LC column.
Pore Size | 120 Å |
---|---|
Stationary Phase | Hydrophobic Alkyl Chain with a Carboxyl Terminus |
Temperature | 50°C |
Phase | Reversed Phase, Ion Exchange, Ion Exclusion, HILIC |
Endcapped | Proprietary |
Column Type | Mixed Mode |
Green Features | Responsibly packaged |
Surface Area | 300 m²/g |
Product Line | Acclaim |
USP Type | L85 |
Thermo Scientific™ Aquasil™ 5μm C18 HPLC Columns, 5?m Particle Size
Thermo ScientificTM AquasilTM 5μm C18 HPLC Columns are available in limited dimensions. Please contact Customer Service for more details.
Pore Size | 100 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 12% |
Stationary Phase | C18 |
Phase | Reversed Phase |
For Use With | LC/MS |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 310 m²/g |
USP Type | L1 |
Column Format | Analytical Column |
Thermo Scientific™ Aquasil™ 3μm C18 HPLC Columns
Available in limited dimensions. Please contact Customer Service for more details.
Pore Size | 100 Å |
---|---|
Particle Size | 3 μm |
Carbon Load | 12% |
Stationary Phase | C18 |
Phase | Reversed Phase |
For Use With | LC/MS |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 310 m²/g |
USP Type | L1 |
Column Format | Analytical Column |
MilliporeSigma™ Supelco™ Ascentis™ Express F5, 2.7 μm HPLC Column
The pentafluorophenylpropyl stationary phase of Ascentis Express F5 provides a stable reversed phase packing with electron-deficient phenyl rings due to the presence of electronegative fluorines.
MilliporeSigma™ Supelco™ Ascentis™ Express 90 Å PFAS Delay, 2.7 μm HPLC Column
The highly retentive endcapped silane of the Ascentis™ Express PFAS Delay column provides high retention of PFAS compounds across various mobile phase conditions and is used to delay background instrument.
Pore Size | 90 Å |
---|---|
Particle Size | 2.7 μm |
Temperature | <60°C |
Matrix | Fused-Core™ Silica Particle Platform Particle Platform Superficially Porous Particle |
Length (Metric) | 5 cm |
Column Type | Reversed Phase |
pH | 2 to 9 |
Quantity | 1 Ea. |
Material | Stainless Steel |
Technique | HPLC, LC/MS |
Surface Area | 135 m2/g |
Max. Pressure | 600 bar |
Thermo Scientific™ EASY-Spray™ PepMap™ Neo UHPLC Columns
Separate challenging peptide mapping samples with Thermo Scientific™ EASY-Spray™ PepMap™ Neo UHPLC columns.
Pore Size | 100 Å |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
For Use With (Application) | Bottom-up Proteomics, LC-MS |
Surface Area | 450 m2/g |
Max. Pressure | 22,000 psi (1500 bar) |
Column Format | Analytical Column, EASY-Spray™ |
Particle Size | 2 μm |
Carbon Load | 15% |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Diameter (Metric) | 75 μm |
pH | 2 to 8 |
Product Line | Easy Spray |
USP Type | L1 |